(Swedish)Independent thesis Basic level (university diploma), 15 credits / 22,5 HE creditsStudent thesis. Regelsamlingen för byggande innehåller Boverkets byggregler, BBR, med • Regelsamling för konstruktion – Boverkets konstruktionsregler, BKR, . Building permit. On most occasions, you need a building permit if you wish to build a new house, build an addition to your house or if you want.

Author: Goltikora Doujin
Country: Croatia
Language: English (Spanish)
Genre: Software
Published (Last): 22 August 2008
Pages: 451
PDF File Size: 17.3 Mb
ePub File Size: 2.22 Mb
ISBN: 768-8-33293-995-6
Downloads: 15671
Price: Free* [*Free Regsitration Required]
Uploader: Saramar

The relationship between the snow load form factor and roof structure is presented below. Each example is calculated in accordance with three different methods, two taken from BKR and one from Eurocode 2. Roof without thermal insulation.

Konstrkutionsregler load pull — self-weight.

The results of these calculations are presented in Table 3. The results in Table 2. The form factor m is used for calculating the dimensions of the cladding. This reinforcement should be installed along the entire beam, whether it is needed to achieve sufficient strength or not. Boverkets Konstruktionsregler BKR 94 design standards. This thesis aims to show what impact this change from Boverkets structural design rules BKR to the Eurocode will have on the dimensioning of shear reinforcement and the calculation of deformation in concrete beams.

The information presented is suitable for single and double pitched roofs. The value qk is determined based on the reference wind speed vref, the type of terrain, and the height of the building.

Eurocode 2 provides a clearer definition of how much deflection konstuktionsregler be allowed, it was not supplied in Boverkets structural design rules.

Form factor maximum values are specified below in roof schemes according to the roof slope. The snow load on the roof is defined by the characteristic value skwhich is calculated as the product of the snow load reference value s0 and the form factor m. Compared to table 2. The form factor is increased in shadow zones. Later, in conjunction with the technical monstruktionsregler and start-up statement, the building committee shall deal with the technical property requirements regarding dwelling design and other technical property requirements.

  ABC TEOLOGII DOGMATYCZNEJ PDF

In order to demonstrate the differences in structural design, with respect to shear force, three examples are calculated. It is assumed that the length and width of the building are twice as long as the height to the ridge of the roof.

The reason for the introduction bkverkets the Eurocode is to try and eliminate trade barriers between member states.

Regelsamling för konstruktion: Boverkets konstruktionsregler, BKR – Google Books

Konstruktionsreg,er load on walls. Form factor m is used for selecting the fixing elements of roofing and determining their dimensions. The municipal building committee shall, among other things, assess whether the design requirements bovermets fulfilled. When you build a building you need to follow the building code. The fact that the partial safety factor is not part of the Eurocode equations for determining the shear resistance in the same manner as it is in BKR, also contributes to the difference in the values.

Login LT EN e.

Swedish Regulations for building works

The municipal building committee also has supervisory responsibility for the building works. This is explained by the differences in how the creep rate is determined in the different methods. Boverket publishes the Swedish building code.

Taking into account the requirement of minimum reinforcement, table 2. If both the length and width of the building are twice as long as the height of the roof ridge, the fixing elements must be selected by taking into account the tensile load in proportion to the following form factor values. The partial factors method is applied.

The effect of wind load on the roof and wall cladding is determined by the form factor and the characteristic value of wind pressure qk. These two methods are used to calculate how much a beam deforms at different relative humidity.

All measurements are calculated based on the following documents and conditions Sweden: You can also find general information about accessibility, dwelling design, obligatory ventilation control and about the Swedish regulatory hierarchy. Then find the value qk in the tables according to the type of terrain and the building height.

  CONSTRUCTION PROJECT MANAGEMENT PLANNING SCHEDULING AND CONTROLLING BY K.K.CHITKARA PDF

Please use this url to cite or link to this publication: The tables of roof dimensions do not take wind load into account.

Boverkets konstruktionsregler eks-10

If the wind blows from a certain type of terrain towards a different terrain, the wind load remains konstrukgionsregler same for the first two kilometers of the new type of terrain. Konstruuktionsregler building code in Sweden contains mandatory provisions and general recommendations. The load reduction factor Y is found in the following table. Boverket Boverket drafts mandatory provisions and general recommendations in Boverket’s Building Regulations.

Go to the page menu Go to the page content. The form factor m depends on wind direction and the form of the building as presented in the table below and on the next page. The bovegkets change to the rules for structural shear design is the requirement for minimum shear reinforcement in concrete beams.

The municipal building committee The municipal building committee shall, among other things, assess whether the design requirements are fulfilled.

The regulations you need to know and follow depend on what you want to build or alter. Roof with thermal insulation. The practical significance of this difference is very small; it only emerges in this thesis when the center distance between the shear reinforcements are determined in example tree. To examine differences between the calculations of deformation, one method from BKR and one from Eurocode 2 is used. The value of the wind speed vref is selected based on the location of the building.

The distance is larger according to Eurocode compared to BKR.