ASTM D882 02 PDF

ASTM D – Valid from. 10/04/ Information provider. American Society of Testing and Materials. Author. American Society for Testing and Materials. Tensile Testing of Thin Plastic Sheeting (Film) ASTM D Scope: Tensile tests measure the force required to break a specimen and the extent to which the. Buy ASTM D TEST METHOD FOR TENSILE PROPERTIES OF THIN PLASTIC SHEETING from SAI Global.

Author: Tosho Yozshugul
Country: Guadeloupe
Language: English (Spanish)
Genre: Travel
Published (Last): 22 May 2007
Pages: 44
PDF File Size: 8.89 Mb
ePub File Size: 1.35 Mb
ISBN: 137-2-86274-836-3
Downloads: 93637
Price: Free* [*Free Regsitration Required]
Uploader: Grogul

Inspection Validating the specifications, value and safety of your raw materials, products and assets.

Tensile Properties (Sheet) ASTM D

Formally confirming that your products and services meet all trusted external and internal standards. Standard test fixtures are installed inside the chamber, and testing is conducted inside the controlled thermal environment the same as it would be at ambient temperature.

The following calculations can be made from tensile test results:. Historical Version s – view previous versions of standard. Enabling you to identify and mitigate the intrinsic risk in your ast, supply chains and business processes. In that sense, caution is advised in utilizing TEB test results for end-use design applications. Send us a request Wilton UK: ISO allows for additional specimen configurations, specifies different test speeds, and requires an extensometer or gage marks on the specimen.

ISO allows for additional specimen configurations, specifies different test speeds, and requires an extensometer or gage marks on the specimen. Tensile tests produce d88 stress-strain diagram, which is used to determine tensile modulus. Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards. Work Item s – proposed revisions of this standard.

The values in parentheses are provided for information only. Note 1—Film has been arbitrarily defined as sheeting having nominal thickness not greater than 0. Testing Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards.

  FORMULAR AUSFUHRBESCHEINIGUNG PDF

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. ASTM D uses astmm x 6″ strips die cut from thin sheet or film. This test method is similar to ISObut is not considered technically equivalent. Tensile tests measure the force required to break a specimen and the extent to which the specimen stretches or elongates to that breaking point.

Tensile Properties (Sheet) ASTM D882

A thermal chamber is satm on the Universal Test machine. For many materials, there can be a specification that requires the use of this test method, but with some procedural modifications that take precedence when adhering to the specification. Link to Active This link will always route to the current Active version of the standard.

The data is often used to specify a material, to design parts to withstand application force and as a quality control check of materials. Whether your business is local or global, we can ensure your products meet quality, health, environmental, safety, astmm social accountability standards for virtually any market around the world.

The chamber is designed to allow the f882 mounts from the base and crosshead of the Universal Tester to pass through the top and bottom of the chamber.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. For ASTM D the test speed and grip d8822 are based on the elongation to break of the material.

Referenced Documents purchase separately The documents listed below are referenced c882 the subject standard but are not provided as part of the standard. It is used to evaluate materials that are subjected to heavy abuse or that can stall web transport equipment in the event of a machine malfunction aztm end-use applications.

Elongation and tensile modulus can be calculated from crosshead displacement, or with an extensometer. Global Reach Intertek is the industry leader with over 42, people in 1, locations in over countries. Note 2—Tensile properties of plastics 1. It is the responsibility of the user of this standard to establish appropriate dd882, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

  DX3E MANUAL PDF

Certification Formally confirming that your products and services meet all trusted external and internal standards.

Consequently, where precise comparative results are desired, these factors must be carefully controlled. Specimens are placed in the grips of the Universal Tester and pulled until failure. The modulus determination is generally based on the use of grip separation as a measure of extension; however, the desirability of using extensometers, as described in 6.

Therefore, it is advisable to refer to that material specification before using this test method. Assurance Enabling you to identify and mitigate the intrinsic risk in your operations, supply chains and business processes. Tensile properties can vary with specimen thickness, method of preparation, speed of testing, type of grips used, and manner of measuring extension. The following calculations can be made from tensile test results: Work Item s – proposed revisions of this standard.

This test method shall be used for referee purposes, unless otherwise indicated in particular material specifications.

Active view current version of standard. Validating the specifications, value and safety of your raw materials, products and assets. Since the physical properties of many materials especially thermoplastics can vary depending on ambient temperature, it is sometimes appropriate to test materials at temperatures that simulate the intended end use environment. The size of the chamber places a limitation on the maximum elongation that can be reached.

Film is defined in Terminology D as an optional term for sheeting having a nominal thickness no greater than 0.